Request list for heavy power using devices.

Heavy power request list

On the event there are different pieces of equipment that requere power most of them are your normale 1 phase 16A schuko plug.
But for al those devices that require more power, 3 phase 16A and up (those red CEE plugs) we want to know about those so it can help us plan the grid.
So please fill out the form below with the equipment you have that is more then ~9KW (3 phase 16A red cee plug) and up.

If you have any questions mailing list: nuts@lists.why2025.org

example

EXAMPLE!

List of requests
Team location equipment power usage and plug type note Nuts approval nuts note
Team:Waste boneyard garbage compactor 3 phase 16A CEE to get rid of carbage - -
Team:Productiehuis main stage stage power 3 phase 200A powerlock power for main stage - -

EXAMPLE!

request list

List of requests
Team location equipment power usage and plug type note Nuts approval nuts note
Team:Shuttle Parking area BEV Charging 40kWp, 63A CEE topping up Shuttle vans Including charge infrastructure for up to 8 connections
Team:NOC Datacenter 4x7KW air conditioning 28KW ,32A CEE cooling Datacenter -
Team:NOC Datacenter servers 2x 32A CEE seperate feed servers -
Team:NOC Datenklo (56x) switches 1x 16A schuko, no shared RCD/FUSES, prevent going down. switches if datenklo if not beside a power point a extension cord is needed. can this be supplied by NUTS?
Piiindakaas Jacuzzi Jacuzzi 220V, 16A, schuko not sure yet tbd -
Team:On-site_transportation LSD Electric Telehandler normal charge 3 kW (240 V / 16 A) blue CEE, quick charge 18 kW (415 V / 32 A) normal charge might be enough, maybe quick charge if needed at shuttle charging area. Spec sheet -
Team:Safety-Fire Safety village AC, hot water Stopcontact 230V 2x vrije groep (2x CEE 230V/16A) Housing 'afkoelruimte' -
Team:Safety-Fire Safety village AC, Nighttime-Cooking, washing machine, hot water Stopcontact 230V 2x vrije groep (2x CEE 230V/16A) Housing 'piketdienst' -
Team:Safety-Fire Safety village AC, hot water Stopcontact 230V 2x vrije groep (2x CEE 230V/16A) Housing 'centrale post' -
Team:Safety-Fire Safety village hot water Stopcontact 230V 1x vrije groep (1x CEE 230V/16A) Firt-aid tent -
Team:Volunteers Heaven hot water & kitchen equipment A lot (details will follow) Heaven tbd -
Team:Warehouse Warehouse 4 portacabins 1x 32A red uplink, 3x 32 A short link (assumption! to be confirmed with rental company) will probably only use <5 kW in practice; at most twice that, when it's very cold or hot tbd -
Team:Foodcourt Foodcourt Foodtrucks & cooling container 67kW Peak usage, 9 trucks, cooling container (13kW 32A CEE) Total: 13x 16A groups. 4x 32A CEE - tbd -
Team:Bar Bar Foodcourt (+ backstage) Bar equipment ~54kW 4x32A CEE + 12x 16A group See Team:Bar page for full table. tbd -
Team:Bar Bar Main Stage Bar equipment ~27kW, 1x32A CEE 5-Pole + 8x 16A group See Team:Bar page for full table. tbd -
Team:Bar Bar Arcade Bar equipment ~30kW, 1x32A CEE 5-Pole + 9x 16A group See Team:Bar page for full table. tbd -
Team:Ticket_&_Entrance Entrance Charging laptops, lamps 5x Stopcontact 230V distrib. over two tables in 5by10 tent tbd -
Team:CTF CTF Tent Workspaces for 75 visitors + lighting (led), a fridge, water cooker & networking equipment All normal 230v sockets We provided a floorplan via email. We requested power strips from Team:Warehouse tbd -
- - - - - tbd -